{"id":603,"date":"2020-01-14T19:20:56","date_gmt":"2020-01-14T19:20:56","guid":{"rendered":"http:\/\/www.hymark.net\/news\/?p=603"},"modified":"2020-02-05T15:10:14","modified_gmt":"2020-02-05T15:10:14","slug":"seamlessly-switch-between-two-ssi-encoders-with-if11","status":"publish","type":"post","link":"http:\/\/www.hymark.net\/news\/seamlessly-switch-between-two-ssi-encoders-with-if11\/","title":{"rendered":"Seamlessly Switch Between Two Encoders with IF11"},"content":{"rendered":"<p>{&#8220;main-title&#8221;:{&#8220;component&#8221;:&#8221;hc_title&#8221;,&#8221;id&#8221;:&#8221;main-title&#8221;,&#8221;subtitle&#8221;:&#8221;&#8221;,&#8221;title_content&#8221;:{&#8220;component&#8221;:&#8221;hc_title_base&#8221;,&#8221;id&#8221;:&#8221;title-base&#8221;,&#8221;image&#8221;:&#8221;&#8221;,&#8221;breadcrumbs&#8221;:false,&#8221;white&#8221;:true},&#8221;title&#8221;:&#8221;Seamlessly Switch Between Two Encoders with IF11&#8243;},&#8221;section_5ZtkF&#8221;:{&#8220;component&#8221;:&#8221;hc_section&#8221;,&#8221;id&#8221;:&#8221;section_5ZtkF&#8221;,&#8221;section_width&#8221;:&#8221;&#8221;,&#8221;animation&#8221;:&#8221;&#8221;,&#8221;animation_time&#8221;:&#8221;&#8221;,&#8221;timeline_animation&#8221;:&#8221;&#8221;,&#8221;timeline_delay&#8221;:&#8221;&#8221;,&#8221;timeline_order&#8221;:&#8221;&#8221;,&#8221;vertical_row&#8221;:&#8221;&#8221;,&#8221;box_middle&#8221;:&#8221;&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;section_content&#8221;:[{&#8220;component&#8221;:&#8221;hc_column&#8221;,&#8221;id&#8221;:&#8221;column_vtfQF&#8221;,&#8221;column_width&#8221;:&#8221;col-md-12&#8243;,&#8221;animation&#8221;:&#8221;&#8221;,&#8221;animation_time&#8221;:&#8221;&#8221;,&#8221;timeline_animation&#8221;:&#8221;&#8221;,&#8221;timeline_delay&#8221;:&#8221;&#8221;,&#8221;timeline_order&#8221;:&#8221;&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;main_content&#8221;:[{&#8220;component&#8221;:&#8221;hc_image&#8221;,&#8221;id&#8221;:&#8221;nXEJb&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;image&#8221;:&#8221;http:\/\/www.hymark.net\/news\/wp-content\/uploads\/2020\/01\/IF11-features.png|250|750|607&#8243;,&#8221;alt&#8221;:&#8221;&#8221;,&#8221;thumb_size&#8221;:&#8221;large&#8221;},{&#8220;component&#8221;:&#8221;hc_space&#8221;,&#8221;id&#8221;:&#8221;GPK3K&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;size&#8221;:&#8221;&#8221;,&#8221;height&#8221;:&#8221;&#8221;},{&#8220;component&#8221;:&#8221;hc_wp_editor&#8221;,&#8221;id&#8221;:&#8221;Xhugf&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;editor_content&#8221;:&#8221;IF11 is designed for contactless (non mechanical), bounce-free switching between two SSI encoders and one SSI Master unit.\\n\\nThe switching operation is under control of a remote signal (HTL, 24 V). Moreover, there is an <strong>automatic internal synchronization<\/strong> to the next SSI signal pause, avoiding fragmented SSI telegrams and wrong information while commutation is in progress.\\n\\nTypical applications can be found in&nbsp;<strong>handling and conveyor technology<\/strong>, where one Master unit must evaluate the signals of two independent SSI encoders for summing or differential information.&nbsp; We can find applications also in&nbsp;<strong>drives and automation,<\/strong>&nbsp;such as automatic roll change \u201con the fly\u201d or redundant systems using several encoders for safety requirements.\\n\\nIF11 uses a narrow and space-saving plastic housing, suitable for DIN rail mounting (according to IEC\/EN 60715). Two LEDs are mounted on the front panel for easy diagnostics.&#8221;},{&#8220;component&#8221;:&#8221;hc_space&#8221;,&#8221;id&#8221;:&#8221;BUcqG&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;size&#8221;:&#8221;s&#8221;,&#8221;height&#8221;:&#8221;&#8221;},{&#8220;component&#8221;:&#8221;hc_image&#8221;,&#8221;id&#8221;:&#8221;NNHk1&#8243;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;image&#8221;:&#8221;http:\/\/www.hymark.net\/news\/wp-content\/uploads\/2020\/01\/IF11-operation-diagram.png|250|528|610&#8243;,&#8221;alt&#8221;:&#8221;&#8221;,&#8221;thumb_size&#8221;:&#8221;large&#8221;},{&#8220;component&#8221;:&#8221;hc_space&#8221;,&#8221;id&#8221;:&#8221;zz0sN&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;size&#8221;:&#8221;&#8221;,&#8221;height&#8221;:&#8221;&#8221;},{&#8220;component&#8221;:&#8221;hc_table&#8221;,&#8221;id&#8221;:&#8221;UG6f2&#8243;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;table&#8221;:{&#8220;component&#8221;:&#8221;this&#8221;,&#8221;id&#8221;:&#8221;sub3_UG6f2&#8243;,&#8221;c3_1_header&#8221;:&#8221;Technical Specifications&#8221;,&#8221;c3_2_header&#8221;:&#8221;&#8221;,&#8221;c3_3_header&#8221;:&#8221;&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;&#8221;,&#8221;c3_3_content&#8221;:&#8221;&#8221;,&#8221;rows&#8221;:[{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;3EVKB&#8221;,&#8221;c3_1_content&#8221;:&#8221;<strong>Power supply<\/strong>&#8220;,&#8221;c3_2_content&#8221;:&#8221;Input voltage:&#8221;,&#8221;c3_3_content&#8221;:&#8221;12&#8230;30 VDC&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;5LAdz&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Protection circuit:&#8221;,&#8221;c3_3_content&#8221;:&#8221;reverse polarity protection&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;11ypD&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Ripple:&#8221;,&#8221;c3_3_content&#8221;:&#8221;\u226410 % at 24 VDC&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;6mTJM&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Consumption:&#8221;,&#8221;c3_3_content&#8221;:&#8221;approx. 50 mA (unloaded)&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;B6F7K&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Connections:&#8221;,&#8221;c3_3_content&#8221;:&#8221;screw terminals, 1.5 mm\u00b2\/ AWG 16&#8243;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;zdwHw&#8221;,&#8221;c3_1_content&#8221;:&#8221;<strong>Encoder supply<\/strong>&#8220;,&#8221;c3_2_content&#8221;:&#8221;Number of outputs: &#8220;,&#8221;c3_3_content&#8221;:&#8221;2&#8243;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;uVaQO&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Output voltage:&#8221;,&#8221;c3_3_content&#8221;:&#8221;corresponds to the power supply voltage minus approx. 2 V&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;R93DK&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Output current:&#8221;,&#8221;c3_3_content&#8221;:&#8221;2 x 125 mA&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;meaFd&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Protection circuit:&#8221;,&#8221;c3_3_content&#8221;:&#8221;short circuit proof&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;4OfwX&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Connections:&#8221;,&#8221;c3_3_content&#8221;:&#8221;screw terminals, 1.5 mm\u00b2\/ AWG 16&#8243;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;mkgVP&#8221;,&#8221;c3_1_content&#8221;:&#8221;<strong>SSI inputs<\/strong>&#8220;,&#8221;c3_2_content&#8221;:&#8221;Number of inputs:&#8221;,&#8221;c3_3_content&#8221;:&#8221;2&#8243;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;u0GzY&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Signal levels:&#8221;,&#8221;c3_3_content&#8221;:&#8221;RS422&#8243;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;PJv3c&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Frequency range:&#8221;,&#8221;c3_3_content&#8221;:&#8221;min. 100 kHz &#8230; max. 1 MHz&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;q3zax&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Connections:&#8221;,&#8221;c3_3_content&#8221;:&#8221;screw terminals, 1.5 mm\u00b2\/ AWG 16&#8243;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;wKFZy&#8221;,&#8221;c3_1_content&#8221;:&#8221;<strong>Control input<\/strong>&#8220;,&#8221;c3_2_content&#8221;:&#8221;Signal level:&#8221;,&#8221;c3_3_content&#8221;:&#8221;HTL, 24 V&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;4szT3&#8243;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Function:&#8221;,&#8221;c3_3_content&#8221;:&#8221;switchover for SSI encoder&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;F9obB&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Connections:&#8221;,&#8221;c3_3_content&#8221;:&#8221;screw terminals, 1.5 mm\u00b2\/ AWG 16&#8243;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;sVjFZ&#8221;,&#8221;c3_1_content&#8221;:&#8221;<strong>SSI output<\/strong>&#8220;,&#8221;c3_2_content&#8221;:&#8221;Number of outputs:&#8221;,&#8221;c3_3_content&#8221;:&#8221;1&#8243;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;2yS9V&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Signal levels:&#8221;,&#8221;c3_3_content&#8221;:&#8221;RS422&#8243;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;70mNk&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Connections:&#8221;,&#8221;c3_3_content&#8221;:&#8221;screw terminals, 1.5 mm\u00b2\/ AWG 16&#8243;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;0xgOI&#8221;,&#8221;c3_1_content&#8221;:&#8221;<strong>Processing data<\/strong>&#8220;,&#8221;c3_2_content&#8221;:&#8221;Delay time:&#8221;,&#8221;c3_3_content&#8221;:&#8221;output <----> input: 100 ns&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;ek1SB&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;SSI interval time:&#8221;,&#8221;c3_3_content&#8221;:&#8221;min. 25 \u03bcs&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;QsR0a&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Propagation delay:&#8221;,&#8221;c3_3_content&#8221;:&#8221;-6V&#8230; + 6V&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;Qg5IG&#8221;,&#8221;c3_1_content&#8221;:&#8221;<strong>Display elements<\/strong>&#8220;,&#8221;c3_2_content&#8221;:&#8221;Green LED:&#8221;,&#8221;c3_3_content&#8221;:&#8221;ready for operation&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;hNDYM&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Yellow LED:&#8221;,&#8221;c3_3_content&#8221;:&#8221;switching state of the encdoer switch&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;ni5Id&#8221;,&#8221;c3_1_content&#8221;:&#8221;<strong>Housing<\/strong>&#8220;,&#8221;c3_2_content&#8221;:&#8221;Material:&#8221;,&#8221;c3_3_content&#8221;:&#8221;plastic&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;JK1hf&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Mounting:&#8221;,&#8221;c3_3_content&#8221;:&#8221;35 mm top hat rail (according to EN 60715)&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;EZAFX&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Dimensions (W x H x D):&#8221;,&#8221;c3_3_content&#8221;:&#8221;22.5 x 121 x 112 mm&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;UWLOU&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Protection class:&#8221;,&#8221;c3_3_content&#8221;:&#8221;IP20&#8243;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;wnAUi&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Weight:&#8221;,&#8221;c3_3_content&#8221;:&#8221;approx. 100 g&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;zFsHj&#8221;,&#8221;c3_1_content&#8221;:&#8221;<strong>Ambient Temperature<\/strong>&#8220;,&#8221;c3_2_content&#8221;:&#8221;Operation:&#8221;,&#8221;c3_3_content&#8221;:&#8221;0 \u00b0C &#8230; +45 \u00b0C  \/ +32 &#8230; +113 \u00b0F (not condensing)&#8221;},{&#8220;component&#8221;:&#8221;repeater_item&#8221;,&#8221;id&#8221;:&#8221;pAU4b&#8221;,&#8221;c3_1_content&#8221;:&#8221;&#8221;,&#8221;c3_2_content&#8221;:&#8221;Storage:&#8221;,&#8221;c3_3_content&#8221;:&#8221;-25 \u00b0C &#8230; +70 \u00b0C  \/ -13 &#8230; +158 \u00b0F (not condensing)&#8221;}]},&#8221;tab_index&#8221;:&#8221;2&#8243;,&#8221;style&#8221;:&#8221;&#8221;,&#8221;advanced&#8221;:false,&#8221;data_options&#8221;:&#8221;&#8221;},{&#8220;component&#8221;:&#8221;hc_space&#8221;,&#8221;id&#8221;:&#8221;rdNyr&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;size&#8221;:&#8221;&#8221;,&#8221;height&#8221;:&#8221;&#8221;},{&#8220;component&#8221;:&#8221;hc_pt_navigation&#8221;,&#8221;id&#8221;:&#8221;VTsFE&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;post_type_slug&#8221;:&#8221;post&#8221;,&#8221;archive_link&#8221;:&#8221;&#8221;,&#8221;previous_text&#8221;:&#8221;Previous Article&#8221;,&#8221;next_text&#8221;:&#8221;Next Article&#8221;}]}],&#8221;section_settings&#8221;:&#8221;&#8221;},&#8221;column_qmCEU&#8221;:{&#8220;id&#8221;:&#8221;column_qmCEU&#8221;,&#8221;main_content&#8221;:{&#8220;component&#8221;:&#8221;hc_space&#8221;,&#8221;id&#8221;:&#8221;rdNyr&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;size&#8221;:&#8221;&#8221;,&#8221;height&#8221;:&#8221;&#8221;}},&#8221;scripts&#8221;:{},&#8221;css&#8221;:{},&#8221;css_page&#8221;:&#8221;&#8221;,&#8221;template_setting&#8221;:{&#8220;settings&#8221;:{&#8220;id&#8221;:&#8221;settings&#8221;}},&#8221;template_setting_top&#8221;:{},&#8221;page_setting&#8221;:{&#8220;settings&#8221;:[&#8220;lock-mode-off&#8221;]},&#8221;post_type_setting&#8221;:{&#8220;settings&#8221;:{&#8220;image&#8221;:&#8221;http:\/\/www.hymark.net\/news\/wp-content\/uploads\/2020\/01\/IF11-326&#215;200-1.png|200|326|611&#8243;,&#8221;excerpt&#8221;:&#8221;IF11 allows an SSI Master to switch data transmission between two SSI encoders. By means of a 24V CTRL digital commutation signal, SSI telegrams switch from one encoder to the other. An automatic internal synchronisation guarantees a correct information flow at changeover.&#8221;,&#8221;extra_1&#8243;:&#8221;&#8221;,&#8221;extra_2&#8243;:&#8221;&#8221;,&#8221;icon&#8221;:{&#8220;icon&#8221;:&#8221;&#8221;,&#8221;icon_style&#8221;:&#8221;&#8221;,&#8221;icon_image&#8221;:&#8221;&#8221;}}}}<\/p>\n","protected":false},"excerpt":{"rendered":"<p>{&#8220;main-title&#8221;:{&#8220;component&#8221;:&#8221;hc_title&#8221;,&#8221;id&#8221;:&#8221;main-title&#8221;,&#8221;subtitle&#8221;:&#8221;&#8221;,&#8221;title_content&#8221;:{&#8220;component&#8221;:&#8221;hc_title_base&#8221;,&#8221;id&#8221;:&#8221;title-base&#8221;,&#8221;image&#8221;:&#8221;&#8221;,&#8221;breadcrumbs&#8221;:false,&#8221;white&#8221;:true},&#8221;title&#8221;:&#8221;Seamlessly Switch Between Two Encoders with IF11&#8243;},&#8221;section_5ZtkF&#8221;:{&#8220;component&#8221;:&#8221;hc_section&#8221;,&#8221;id&#8221;:&#8221;section_5ZtkF&#8221;,&#8221;section_width&#8221;:&#8221;&#8221;,&#8221;animation&#8221;:&#8221;&#8221;,&#8221;animation_time&#8221;:&#8221;&#8221;,&#8221;timeline_animation&#8221;:&#8221;&#8221;,&#8221;timeline_delay&#8221;:&#8221;&#8221;,&#8221;timeline_order&#8221;:&#8221;&#8221;,&#8221;vertical_row&#8221;:&#8221;&#8221;,&#8221;box_middle&#8221;:&#8221;&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;section_content&#8221;:[{&#8220;component&#8221;:&#8221;hc_column&#8221;,&#8221;id&#8221;:&#8221;column_vtfQF&#8221;,&#8221;column_width&#8221;:&#8221;col-md-12&#8243;,&#8221;animation&#8221;:&#8221;&#8221;,&#8221;animation_time&#8221;:&#8221;&#8221;,&#8221;timeline_animation&#8221;:&#8221;&#8221;,&#8221;timeline_delay&#8221;:&#8221;&#8221;,&#8221;timeline_order&#8221;:&#8221;&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;main_content&#8221;:[{&#8220;component&#8221;:&#8221;hc_image&#8221;,&#8221;id&#8221;:&#8221;nXEJb&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;image&#8221;:&#8221;http:\/\/www.hymark.net\/news\/wp-content\/uploads\/2020\/01\/IF11-features.png|250|750|607&#8243;,&#8221;alt&#8221;:&#8221;&#8221;,&#8221;thumb_size&#8221;:&#8221;large&#8221;},{&#8220;component&#8221;:&#8221;hc_space&#8221;,&#8221;id&#8221;:&#8221;GPK3K&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;size&#8221;:&#8221;&#8221;,&#8221;height&#8221;:&#8221;&#8221;},{&#8220;component&#8221;:&#8221;hc_wp_editor&#8221;,&#8221;id&#8221;:&#8221;Xhugf&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;editor_content&#8221;:&#8221;IF11 is designed for contactless (non mechanical), bounce-free switching between two SSI encoders and one SSI Master unit.\\n\\nThe switching operation is under control of a remote signal (HTL, 24 V). Moreover, there is an automatic internal synchronization to the next SSI signal pause, avoiding fragmented SSI telegrams and wrong [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[4],"tags":[],"_links":{"self":[{"href":"http:\/\/www.hymark.net\/news\/wp-json\/wp\/v2\/posts\/603"}],"collection":[{"href":"http:\/\/www.hymark.net\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.hymark.net\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.hymark.net\/news\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.hymark.net\/news\/wp-json\/wp\/v2\/comments?post=603"}],"version-history":[{"count":12,"href":"http:\/\/www.hymark.net\/news\/wp-json\/wp\/v2\/posts\/603\/revisions"}],"predecessor-version":[{"id":623,"href":"http:\/\/www.hymark.net\/news\/wp-json\/wp\/v2\/posts\/603\/revisions\/623"}],"wp:attachment":[{"href":"http:\/\/www.hymark.net\/news\/wp-json\/wp\/v2\/media?parent=603"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.hymark.net\/news\/wp-json\/wp\/v2\/categories?post=603"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.hymark.net\/news\/wp-json\/wp\/v2\/tags?post=603"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}